Honeywell Aeris Confort Type 2 with Zenith Demand Valve(1825111) & 45 Minutes Cylinder
Product Details
- Aeris Confort Type 2 – black harness – with Zenith demand valve and Panoramasque full-face mask with 5-point head strap
- Non metallic, ergonomic, flexible back plate
- 3 carry handles
- Compatible with both demand positive pressure quick click valves
- Flame-retardant optional reflective pads accessories available on shoulders
- End of operation alarm whistle integrated
- Polypropelene and aramide black back pack harness
- Panoramasque full face mask with 5 point head strap with polycarbonide lens
- Carbon fibre cylinder (Empty)
- Pressure guage -300 bar -7 Litres ( 45 minutes duration )
- Product Includes 1825111(Valve) ,1824852(Cylinder),1825338(Reflectives)
- Standard: EN 137: 2006 Type 2, SOLAS, MED, IMO, MSC, ISO 23261-3
- Industry:Chemical Industries , Fire Protection Brigades ,Mining and Quarrying , Offshore , Utilities
Related products
-
SCBA - Self Contained Breathing Apparatus0 out of 5
MSA AirHawkII A-A2LB36B00C13AA1 SCBA Nylon Harness With Double Pull Chest Strap 30 Minutes Duration
0 out of 5Product Details
- The new Air Hawk II Air Mask is built upon MSA’s established Air Hawk MMR Air Mask and is a lightweight, durable, and economical SCBA for many industrial IDLH (immediately dangerous to life or health) applications.
- This SCBA fits any budget by keeping its lower-cost options while offering many new choices not offered with any other industrial air mask. In addition, the Air Hawk II Air Mask is available in both low-pressure and high-pressure versions.
- MSA’s Air Hawk II Air Mask is a pressure-demand apparatus designed to maintain a slight positive air pressure inside the face piece during inhalation and exhalation.
- Positive pressure helps to prevent contaminants from seeping in and around the face piece, even if small breaks in the face-to face piece seal should occur.
- The Air Hawk II Air Mask is built from six major components: face piece, carrier and harness assembly, cylinder, first-stage regulator, mask-mounted regulator, and End-of-Service-Time-Indicator (EOSTI).
Face piece
- MSA offers you the choice of two face pieces, the proven Ultra Elite Face piece or new industrial Advantage 4000 Face piece for the Air Hawk II Air Mask.
- Choose from three face piece sizes (small, medium or large) in either Soft Feel Rubber or silicone rubber.
- Nose cups are available in two sizes, standard and large.
The Ultra Elite Face piece features:
- A one-way check valve preventing exhaled air from entering the mask mounted re entering the mask mounted regulator
- A molded polycarbonate lens .a mechanical speaking diaphragm for short-range communications. five adjustable rubber straps for exceptional head comfort, security, and safety optional heat-resistant Kevlar hairnet-style head harness
The Advantage 4000 Face piece features:
- Adapters to convert the Advantage Face piece to a Twin-Cartridge Respirator (using Advantage Cartridges) or an RD40 Face piece
- A one-way check valve preventing exhaled air from entering the mask-mounted regulator
- A molded polycarbonate lens
- Four-point silicone head harness for exceptional comfort and security
- optional polyester net head harness
Airframe Carrier and Harness Assembly
- MSA’s durable AirFrame Carrier and Harnessassembly comes standard with large side handles and a central attachment point to pull workers to safety in rescue scenarios.
- The AirFrame Carrier and Harness distributes the SCBA’s weight over the user’s hips for comfort and stability.
- The composite backplate is made of glass fiberreinforced thermoset plastic and is ergonomically designed with a spine strain relief. Key components are detachable without special tools.
- The assembly’s harness components are available in nylon or high-strength Kevlar. Shoulder straps feature easy-to-release friction buckles to positively retain pull straps.
- A center-pull waist belt system is also incorporated into its design.
- This harness also provides optional shoulder pads, lumbar pad, and chest strap, making this unit the most comfortable industrial air mask on the market today.
- The cylinder band is available in nylon or Kevlar and is secured by an adjustable nylon buckle, allowing the band to retain various cylinder sizes.
- An optional open-form stainless steel cylinder band provides rapid drop-in cylinder replacement, eliminating webbing adjustments and clips.
Cylinders
- MSA offers a choice of three low pressure (2216 psig) 30-minute-rated cylinders for use with this SCBA. Choose carbon-wrapped, fiberglass hoop- wound, or all-aluminum construction cylinders.
- High-pressure (4500 psig) carbon wrapped cylinders are available in 30-, 45- or 60-minute durations.
First Stage Regulator
- The PR-14 Regulator is designed with the fewest number of parts in the industry, with Teflon- coated anodized valve bodies to minimize internal component friction and maximize service life
- The PR-14 Regulator has only 14 replaceable parts and can be maintained without special tools.
Mask Mounted Regulator
- The second-stage Fire Hawk Regulator Features
- A slide-to-connect (S-T-C) or push-to-connect (P-T-C) regulator attachment to meet the widest preference ranges.
- An integrated shutoff prevents cylinder air loss when disconnecting the second-stage regulator from the face piece.
- The Fire Hawk Regulator has only 22 replaceable parts and can be maintained without special tools.
Eosti
- MSA’s Audi-Larm Audible Alarm is an air-actuated continuously-ringing warning bell that automatically sounds when the air-supply cylinder reaches 25% of its rated service life.
-
SCBA - Self Contained Breathing Apparatus0 out of 5
Honeywell 1818411 Carrying Case for SCBA
0 out of 5Honeywell 1818411 Carrying Case for SCBA
-
SCBA - Self Contained Breathing Apparatus0 out of 5
Honeywell T8000 SCBA840E60 Open-Circuit SCBA with 40 Minutes Cylinder & Case
0 out of 5Product Description
- The T8000 is an open circuit self contained compressed breathing apparatus developed by Honeywell Safety Products which complies with the requirements of the latest EN 137, Type 1 standard.
- Comfortable, high-performing and durable it will protect you during any situation or application.
- Honeywell Breathing Apparatus T8000CE Black Harness with Panoramasque Full Face Mask & 6.8 Litre 300 Bar Carbon Composite Cylinder
- EN 137-2006 certified SCBA The SCBA design is base on considering the Chinese working environment and working habit
- Light weight, the total weight only 10.4kg (including 3.8Kg cylinder), suit for long time wearing.
- Full face mask ( Panoramasque )
- Valved pressure vessel
- Backpack with body harness
- Pressure reducer
- Pressure indicator
- Pressure vessel
- PC class 3 with anti scratch treatment VISOR
Applications
- T8000 is optimized for industrial applications. It ensures the best respiratory protection of the wearer in any situation, even with very low rate of oxygen in the air.
- T8000 can be used during 40 minutes with 6.8L 300 bar light composite cylinder for work or rescue/evacuation activities.
Product Specifications
Weight With Cylinder 10 Kg Using Temperature -30°C+60°C Pressure Reducer Input Pressure Up to 330 bar Output 2 outputs of 6-8 bar Type of Reducer Compensated Demand Valve Max Flow (by-pass) 450 I/min Type of LDV Positive pressure, activated when connected to face piece, Airflow stopped automatically when LDV disconnected from face piece
Face piece Skirt and inner mask material EPDM Visor PC class 3 with anti scratch treatment Options Integrated speech diaphragm Pressure Guage Type of Guage Pneumatic Precision class 1.6 Protection Rubber cover Low pressure alarm Activation Pressure 50-60 bar Sound Level >90 dB at ear Air Consumption < 5 l/min Cylinder Volume 6.8L Nominal Pressure 300 bar Testing Pressure 450 bar Type Composite with Aluminium Liner